Sale used Fluke 5320A Multifunction Electrical Tester Calibrator. This unit is in excellent condition, has been fully tested and is guaranteed functional. It comes with a 30 day right of return should it not perform to your expectations.
Package includes:
The 5320A Multifunction Electrical Tester Calibrator combines many functions into a single instrument, replacing the resistors, decade boxes and other custom solutions commonly used to calibrate electrical testers. It's flexible and precise enough to calibrate a wide range of instrumentation.
Multifunction installation testers
The 5320A has all the functionality needed to calibrate installation testers with insulation resistance, continuity, loop, RCD and earth resistance test capabilities.
Portable appliance testers (PATs)
The 5320A has all the functionality needed to calibrate PATs, with insulation resistance, ground bond, leakage current, flash voltage and load test capabilities.
Insulation resistance testers
The 5320A calibrator sources high ohms, high voltage resistors and measures the high voltage output of megohm meters and other portable and bench insulation testers. When calibrating insulation resistance testers up to 1 kV, you can select a wide range of continuously variable resistance values, from 10 kO to 10 GO, with 4 ½ digit resolution and one single value of 100 GO. When calibrating 5 kV insulation testers, the external 10 kV dual function adapter extends the resistors? range up to 10 TO. The adapter functions both as a 1000: 1 voltage divider to 10 kV, and as a x1000 resistance multiplier to 10 TO.
Continuity testers and earth (ground) resistance testers
To calibrate these low ohms testers, a calibrator must be able to source precision low ohms. From its low ohms precision resistors, the 5320A calibrator sources resistance values ranging from 100 mO to 10 kO, with 3 ½ digits of resolution. Choose 2-wire or 4-wire modes for maximum flexibility.
Loop/line impedance testers and ground bond testers
The 5320A calibrator has 16 high power, high current resistors it can source, to increase the resistance of a loop or line by a known amount. Use Scan mode to automatically determine the resistance of the loop, and use Active Loop Compensation mode to compensate for any residual impedance in the loop or line.
Residual-current device (RCD) or ground fault current interrupter (GFCI) testers
The 5320A simulates a circuit breaker (an RCD/GFCI) to verify and calibrate trip current and trip time, with a wide range that enables it to accurately handle most models in this instrument category. For most RCD testers, trip times are calculated to an uncertainty of 0.25 ms, to provide better than 4:1 test uncertainty ratios (TUR). Trip current uncertainty is 1 %, which also provides better than 4:1 TURs in most applications.
Leakage current testers
Simulate a leakage current for direct/ touch, differential and substitute leakage current methods with 4 ½ digit resolution from 0.1 mA to 30 mA. The 5320A lets you choose the method that works best for your test, unlike other calibrators that only offer a single method.
Voltmeters
Many testers have built-in voltmeters. But you don?t need an additional calibrator to test this part of the workload. The model 5320A/VLC calibrator adds a precision voltage source to 600 V with 0.1 % accuracy, to calibrate V ac and V dc meters.
Hipot testers
Electrical safety testing with hipots is an integral part of development and manufacturing of electronic and electrical products, ranging from refrigerators to power supplies to test equipment to cables. Such testing is often required by government regulations to ensure product safety. The Fluke 5320A provides best-in- class hipot calibration of ac and dc voltage. The built-in 1000 V meter measures voltage and current. For voltages over 1 kV, Fluke offers two accessory items: a 10 kV adapter or 40 kV probe. With the 10 kV adapter, ac voltages to 10 kV can be calibrated with 0.5 % accuracy. Either item can be used with the built-in meter to measure voltage or flash voltage over 1000 V.
Medical safety testers
With the broad functionality and high accuracy of the 5320A, calibrating medical safety testers is a snap, allowing you to add these items to your calibration workload.
Fluke 5320A Specificaitions
Precision Low Resistance Source |
|
Ranges | 100 mΩ to 10 kΩ |
Resolution | 3 ½ digits (continuously variable) |
Maximum Current Ranges | 5 mA to 400 mA |
Modes | 2-Wire and 4-Wire |
Best 1 Year Specification | ± 0.2 % of setting |
High Resistance Source (High voltage) | |
Ranges | 10 kΩ to 100 GΩ |
Resolution | 4 ½ digits (continuously variable to 10 GΩ) |
Maximum Voltage Ranges | 55 Vpk to 1575 Vpk |
Best 1 Year Specificatio | ± 0.2 % of setting |
Resistance Multiplier Adapter¹ (for high resistance source) | |
Resistance Ranges | 350 MΩ to 10 TΩ |
Maximum Test Voltage | 5500 V dc |
Best 1 Year Specification | Uncertainty of 5320A resistor to be multiplied ± 1 % of displayed value |
Low Resistance Source (High current) | |
Ranges | 25 mΩ to 1.8 kΩ, 16 values |
Maximum Current Ranges | Continuous: 0.025 A to 30 A Short-term: 0.15 A to 40 A |
Best 1 Year Specification | ± 5 mΩ of setting |
Loop Compensation | Scan Mode: 0 to 10 Ω Active Comp Mode: 0 to 2 Ω |
Loop Compensation Specification | ± 1 % + 15 mΩ (Scan and active comp Mode) Active Loop Compensation available on 5320A/VLC only |
Line Leakage Current Source | |
Ranges | 0.1 mA to 30 mA |
Resolution | 10 uA of setting |
Test Voltage Ranges | 10 to 250 V |
Modes | Passive, Differential, Substitute, Active |
Best 1 Year Specification | ± 0.3% + 1 uA of setting |
Residual Current Device | |
Trip Current Ranges | 3 to 3000 mA |
Trip Current Modes | 0.5xI, 1xl, 1.4xI, 2xI, and 5xI |
Best 1 Year Trip Current Specification | ± 1 % rms |
Trip Time Ranges | 10 to 5000 ms |
Best 1 Year Trip Time Specification | ± 0.25 ms |
Multimeter | |
Voltage Ranges | 0 to 1100 V ac rms or dc |
Voltage Resolution | 4 ½ digits |
Best 1 Year Voltage Specification | ± 0.15% of reading + 5 mV |
Current Ranges | 0 to 30 A ac rms or dc |
Current Resolution | 4 ½ digits |
Best 1 Year Current Specification | ± 0.15% of reading + 0.15 mA |
Phantom Power | 0 to 33 kVA |
Phantom Power Resolution | 3 digits |
Best 1 Year Power Specification | √((V)² + (I)²) |
Hipot Leakage Current Measurement Mode (Multimeter mode) | |
Current Range | 0 to 300 mA acrms or cc |
Current Resolution | 4 ½ digits |
Best 1 Year Specification | ± 0.2% of reading + 0.21 mA |
Hipot Timer Measurement Mode (Multimeter mode) | |
Timer Measurement Range | 0.1 to 999 s |
Timer Resolution | 1 ms |
Best 1 Year Specification | DC: 0.02% + 2 ms AC: 0.02% + 20 ms |
10 kV Divider Adapter¹ (for multimeter input) |
|
Voltage Ranges | 0 to 10 kV ac peak or dc |
Voltage Divider Ratio | 1000:1 |
Best 1 Year Specification | ± 0.3 % of reading + 5 V dc ± 0.5 % of reading + 5 V ac (50 or 60 Hz) |
40 kV Probe² (for multimeter input) Accessory | |
Voltage Ranges | 0 to 40 kV ac peak or dc |
Voltage Divider Ratio | 1000:1 |
Best 1 Year Specification | ± 0.5 % of reading + 10 V dc ± 0.5 % of reading + 10 V ac (50 or 60 Hz) |
Voltage Calibrator Source (5320A/VLC only) | |
Ranges | 3 to 600 V ac or dc |
Voltage Resolution | 4 digits |
Frequency | 40 to 400 Hz |
Frequency Resolution | 3 digits |
Maximum Burden Current | AC: 500 mA DC: 5 mA |
Best 1 Year Current Specification | ± 0.1 % of setting + 9 mV |
General Specifications | |
Warm up Time | 30 minutes |
Operating Temperature | 18 ºC to 28 ºC |
Calibration Temperature (Tcal) | 23º C |
Storage Temperature | - 20 ºC to + 70 ºC |
Operating Altitude | 3,050 m (10,00 ft) |
Storage Altitude | 12,200 m (40,000 ft) |
Power Line | 115/230 V ac ± 10 % (50/60 Hz) |
Power Consumption | 150 VA Maximum |
Safety | Class I, according to EN 61010-1 |
Dimensions | 450 x 480 x 170 mm (17.7 x 18.9 x 6.7 in.) |
Weight | 18 kg (39.7 lbs.) |