ProSoft Technology AN-X4-AB-DHRIO Ethernet Module
Selling Brand New and Original ProSoft Technology AN-X4-AB-DHRIO EtherNet/IP to DH Gateway, Ethernet Module
- Genuine Product
- Technical Support
- Worldwide Shipping
The AN-X4-AB-DHRIO Gateway is designed to help customers initiate a phased migration approach to replacing or upgrading legacy PLC’s, HMI's, Drives, or Flex I/O adapters.
These solutions can be achieved by selecting the corresponding operating mode during initial configuration. The AN-X4-AB-DHRIO has a built-in webserver to view diagnostics, current configuration, upload configuration files, and set the operating mode. It is also DIN Rail Mountable.
| DH+ to EtherNet/IP™ |

1. The operating mode acts as a bridge between an EtherNet/IP and a DH+ network.
- Programming terminals, and/or processors on an EtherNet/IP network can access legacy processors on a DH+ network
- Download to a PLC5 or SLC through RSLinx
- Configured through web browser
- Supports all DH+ baud rates (57.6, 115.2, and 230.4 K baud).

The operating mode helps the communication between an Ethernet-Based processor with legacy processors on a DH+ network.
- Support gathering data without changing existing PLC or SLC hardware
| DH+ to Modbus TCP |
This operating mode allows Modbus TCP Clients to access the PLC data from stations on a Data Highway Plus Network.
- The Modbus TCP server supports up to 128 connections
- Modbus Input and Output Registers are mapped to the PLC/SLC files for each station
- Modbus TCP Unit/Slave ID data is mapped to the Data Highway Plus Station
| HMI |

This operating mode allows legacy PanelViews to be upgraded to a PanelView Plus 6 or PanelView Plus 7 via EtherNet/IP.
- No changes to PLC code required
- Supports up to 8 PanelViews on the same network.
| Drive |

This operating mode supports upgrading legacy Allen Bradley drives on Remote I/O to new EtherNet/IP-enabled drives.
- No changes to PLC code required
- Supports up to 4 EtherNet/IP drives
- Configurable with ¼, ½, and full rack addressing
- Supports all PowerFlex drives on EtherNet/IP.
| Flex I/O Scanner |

This operating mode allows PLC’s on Remote I/O to connect to and control 1794-AENT EtherNet/IP Flex adapters.
- Designed to replace obsolete 1794-ASB adapters
- Supports up to 16 EtherNet/IP connections
- Each adapter and rack of discrete counts as a single connection. Each analog module counts as a single connection.
| Remote I/O Scanner |
This operating mode allows users to replace their existing Remote I/O PLC with a ControlLogix or CompactLogix PAC without having to replace existing racks of I/O.
- Build new controller programs without interrupting existing controls, minimizing downtime
- Supports up to 32 racks of Remote I/O
- Supports all Remote I/O baud rates (57.6, 115.2, and 230.4 K baud), and Remote I/O addressing 0 to 76 octal
- Auto-Configuration utility discovers baud rate and maps discrete I/O, reducing configuration errors
| Remote I/O Adapter |
This operating mode allows PLC’s on Remote I/O to share data with a newer ControlLogix or CompactLogix PAC’s. This mode also allows a ControlLogix processor to monitor Block Transfer and I/O data on an active Remote I/O network without occupying a drop.
- Supports up to 16 EtherNet/IP I/O connections to a Logix processor
- Supports any combination of Remote I/O rack addressing
- Auto-configures rack addressing and baud rate
| Bridge Mode |
This operating mode allows the module to listen to all messages on an Ethernet network and use its “BridgeIP” mapping to forward the messages out of the DH+/BH port. The messages received on the DH+/BH port can be forwarded to the devices connected to its Ethernet port.
- Allows the use of existing Blue Hose cabling for EtherNet/IP communication:
- I/O to Controllers
- HMI to SCADA
- Programming Controllers via PC
- Support for up to 64 AN-X4-BRG, each on different Ethernet network
- DH+ mode supports up to 230k Baud Rate
- Blue Hose mode supports up to 460K Baud Rate
ProSoft AN-X4-AB-DHRIO Specification
| Device type | PLC Ethernet & Communication Module |
| Ports |
|
| Typical Power Consumption | 240 mA @ 12 Vdc or 120 mA @ 24 Vdc |
| Maximum Power Dissipation | 2.9 W |
| Operating Temp | 32°F to 122°F (0ºC to 50ºC) |
| Storage Temperature | -40°F to 185°F (-40ºC to 85ºC) |
| Dimensions | 107 x 98 x 34 mm (4.18 x 3.86 x 1.33 in) Not including connectors |
| Humidity | 5% to 95% RH, with no condensation |